--- title: "Graphiant Failover Testing Performance Results" slug: "graphiant-backbone-resiliency-results" description: "Review Graphiant backbone failover testing results and learn how the platform maintains connectivity during network disruptions." updated: 2026-05-07T20:14:45Z published: 2026-05-07T20:14:45Z canonical: "docs.graphiant.com/graphiant-backbone-resiliency-results" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.graphiant.com/llms.txt > Use this file to discover all available pages before exploring further. # Graphiant Failover Testing Performance Results Graphiant performs failover testing on a yearly basis and publishes the performance results. The failover recovery time for each event is calculated using both Ping and iPerf3 TCP. ## Initial Topologies The two base topologies tested are as follows, where: **Green** arrows = Primary path **Yellow** arrows = Backup path ![Diagram illustrating a single WAN topology with source, regions, and destination connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Single WAN Topology Client(1).png) ![Diagram illustrating a dual WAN topology connecting source and destination through multiple regions.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Resiliency Demo Topo Dual WAN.png) ## Tests Performed The failover tests performed measure recovery time for: - Three events performed ***sequentially***, cumulatively building on each prior event: - [WAN Circuit Failure](/v1/docs/graphiant-backbone-resiliency-results#wan-circuit-failure) (Event 1) - [PoP Failure](/v1/docs/graphiant-backbone-resiliency-results#pop-failure-test) (Event 2) - [Region Failure](/v1/docs/graphiant-backbone-resiliency-results#region-failure-test) (Event 3) - A ***simultaneous*** test of all three above events occurring at once: - [Immediate Region Failure](/v1/docs/graphiant-backbone-resiliency-results#immediate-region-failure-test-event-4) (Event 4) ## WAN Circuit Failure Test (Event 1) In a WAN Circuit failure test, a WAN connection from the Edge to the Core is brought down. ### WAN Circuit Failure in Single WAN #### Topology In the case of a single WAN topology experiencing a primary WAN disconnection, the traffic will move: ***From:*** The primary path to/from the Graphiant PoP ***To:*** The backup path to/from the other PoP in that same region. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating WAN circuit failure in a single WAN topology for client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Single WAN Client(1).png) ![Diagram illustrating WAN circuit failure in a single WAN topology with regions and connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Single WAN Server(3).png) #### Performance Results: WAN Circuit Failure (Event 1) in Single WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 3 | 3 | | 2024 | Server Side | 4 | 2 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 3 | 3 | | 2025 | Server Side | 2 | 3 | ### WAN Circuit Failure in Dual WAN #### Topology In the case of a dual WAN topology experiencing a primary WAN disconnection, the traffic will move: ***From:*** The primary path to/from the Graphiant PoP ***To:*** The backup path to/from the other PoP within the same Graphiant region. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating dual WAN topology with a highlighted circuit failure scenario.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Dual WAN Client1.png) ![Diagram illustrating dual WAN topology and circuit failure for server connectivity.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Dual WAN Server(3).png) #### Performance Results: WAN Circuit Failure (Event 1) in Dual WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 3 | 3 | | 2024 | Server Side | 3 | 2.8 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 2 | 2 | | 2025 | Server Side | 3 | 3 | ## PoP Failure Test (Event 2) In a PoP failure test, all connections from the Edge to a given PoP are brought down. ### PoP Failure in Single WAN #### Topology > [!NOTE] > In the case of a single WAN topology PoP disconnection: > > This is the same topology as the WAN circuit failure test, as the prior disconnection of the single WAN circuit results in that PoP no longer being reachable. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating PoP failure in a single WAN topology on the client side.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Single WAN Client(1).png) ![Diagram illustrating PoP failure in a single WAN topology with source and destination.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Single WAN Server(2).png) #### Performance Results: PoP Failure (Event 2) in Single WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 0 | 0 | | 2024 | Server Side | 0 | 0 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 0 | 0 | | 2025 | Server Side | 0 | 0 | ### PoP Failure in Dual WAN #### Topology In the case of a dual WAN topology, the original backup path to the PoP will be brought down, secondarily to the primary WAN circuit disconnect. The traffic will move: ***From:*** The primary path (originally the backup path prior to Event 1) to/from the primary PoP ***To:*** The backup path to/from the other PoP within that same region. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating dual WAN topology with PoP failure and client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Dual WAN Client(1).png) ![Diagram illustrating dual WAN topology and PoP failure between regions A and B.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Dual WAN Server(3).png) #### Performance Results: PoP Failure (Event 2) in Dual WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 0 | 0 | | 2024 | Server Side | 0 | 0 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 0 | 0 | | 2025 | Server Side | 0 | 0 | ## Region Failure Test (Event 3) In a Region failure test, all connections from the Edge to the secondary PoP in a given region in the Graphiant Core are brought down. ### Region Failure in Single WAN #### Topology In the case of a single WAN topology, the path to the secondary PoP in the region will be brought down, secondarily to the primary PoP disconnect. The traffic will move: ***From:*** The primary path (originally the backup path prior to Event 1) to/from the secondary PoP ***To:*** The path to/from the next closest PoP in a different region within the Graphiant Core. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating region failure in a single WAN topology for client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Client.png) ![Diagram illustrating single WAN topology with region failure and server connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Server(1).png) #### Performance Results: Region Failure (Event 3) in Single WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 81 | 110 | | 2024 | Server Side | 81 | 110 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 76 | 108 | | 2025 | Server Side | 78 | 111 | ### Region Failure in Dual WAN #### Topology In the case of a dual WAN topology, the paths to the secondary PoP in the region will be brought down, secondarily to the primary PoP disconnect. The traffic will move: ***From:*** The primary path (originally the backup path prior to Event 2) to/from the secondary PoP ***To:*** The path to/from the next closest PoP in a different region within the Graphiant Core. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating dual WAN topology with region failure and client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Client(1).png) ![Diagram illustrating dual WAN topology with region failure and connection paths.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Server(2).png) #### Performance Results: Region Failure (Event 3) in Dual WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 58 | 112 | | 2024 | Server Side | 68 | 111 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 59 | 111 | | 2025 | Server Side | 52 | 56 | ## Immediate Region Failure Test (Event 4) In an Immediate Region failure test, all connections from the Edge to a given region in the Graphiant Core are brought down simultaneously. ### Immediate Region Failure in Single WAN #### Topology In the case of a single WAN topology, after the region is immediately unreachable: The traffic will move: ***From:*** The path to the primary PoP within a given region ***To:*** The next closest PoP in a different region within the Graphiant Core. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating region failure in a single WAN topology for client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Client.png) ![Diagram illustrating single WAN topology with region failure and server connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Server(1).png) #### Performance Results: Immediate Region Failure (Event 4) in Single WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 71 | 112 | | 2024 | Server Side | 83 | 114 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 68 | 108 | | 2025 | Server Side | 84 | 107 | ### Immediate Region Failure in Dual WAN #### Topology In the case of a dual WAN topology, after the region is immediately unreachable: The traffic will move: ***From:*** The primary path to the primary PoP within a given region ***To:*** The next closest PoP in a different region within the Graphiant Core. **Red** arrows = Blocked path **Green** arrows = New Primary path **Yellow** arrows = Backup path ![Diagram illustrating dual WAN topology with region failure and client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Client(1).png) ![Diagram illustrating dual WAN topology with region failure and connection paths.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Server(2).png) #### Performance Results: Immediate Region Failure (Event 4) in Dual WAN Topology | Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | | 2024 | Client Side | 73 | 115 | | 2024 | Server Side | 66 | 113 | | **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | Client Side | 70 | 112 | | 2025 | Server Side | 83 | 108 | ## Complete Performance Results per Topology ### Single WAN, Failure on Client Side | Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | --- | | 2024 | 1 | WAN Circuit Failure | 3 | 3 | | 2024 | 2 | add PoP Failure | 0 | 0 | | 2024 | 3 | add Region Failure | 81 | 110 | | 2024 | 4 | Immediate Region Failure | 71 | 112 | | **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | 1 | WAN Circuit Failure | 3 | 3 | | 2025 | 2 | add PoP Failure | 0 | 0 | | 2025 | 3 | add Region Failure | 76 | 108 | | 2025 | 4 | Immediate Region Failure | 68 | 108 | ### Single WAN, Failure on Server Side | Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | --- | | 2024 | 1 | WAN Circuit Failure | 4 | 2 | | 2024 | 2 | add PoP Failure | 0 | 0 | | 2024 | 3 | add Region Failure | 81 | 110 | | 2024 | 4 | Immediate Region Failure | 83 | 114 | | **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | 1 | WAN Circuit Failure | 2 | 3 | | 2025 | 2 | add PoP Failure | 0 | 0 | | 2025 | 3 | add Region Failure | 78 | 111 | | 2025 | 4 | Immediate Region Failure | 84 | 107 | ### Dual WAN, Failure on Client Side | Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | --- | | 2024 | 1 | WAN Circuit Failure | 3 | 3 | | 2024 | 2 | add PoP Failure | 0 | 0 | | 2024 | 3 | add Region Failure | 58 | 112 | | 2024 | 4 | Immediate Region Failure | 73 | 115 | | **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | 1 | WAN Circuit Failure | 2 | 2 | | 2025 | 2 | add PoP Failure | 0 | 0 | | 2025 | 3 | add Region Failure | 59 | 111 | | 2025 | 4 | Immediate Region Failure | 70 | 112 | ### Dual WAN, Failure on Server Side | Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | --- | --- | --- | --- | --- | | 2024 | 1 | WAN Circuit Failure | 3 | 2.8 | | 2024 | 2 | add PoP Failure | 0 | 0 | | 2024 | 3 | add Region Failure | 68 | 111 | | 2024 | 4 | Immediate Region Failure | 66 | 113 | | **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) | | 2025 | 1 | WAN Circuit Failure | 3 | 3 | | 2025 | 2 | add PoP Failure | 0 | 0 | | 2025 | 3 | add Region Failure | 52 | 56 | | 2025 | 4 | Immediate Region Failure | 83 | 108 |