---
title: "Graphiant Failover Testing Performance Results"
slug: "graphiant-backbone-resiliency-results"
description: "Review Graphiant backbone failover testing results and learn how the platform maintains connectivity during network disruptions."
updated: 2026-05-07T20:14:45Z
published: 2026-05-07T20:14:45Z
canonical: "docs.graphiant.com/graphiant-backbone-resiliency-results"
---

> ## Documentation Index
> Fetch the complete documentation index at: https://docs.graphiant.com/llms.txt
> Use this file to discover all available pages before exploring further.

# Graphiant Failover Testing Performance Results

Graphiant performs failover testing on a yearly basis and publishes the performance results.

The failover recovery time for each event is calculated using both Ping and iPerf3 TCP.

## Initial Topologies

The two base topologies tested are as follows, where:

**Green** arrows = Primary path

**Yellow** arrows = Backup path

![Diagram illustrating a single WAN topology with source, regions, and destination connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Single WAN Topology Client(1).png)

![Diagram illustrating a dual WAN topology connecting source and destination through multiple regions.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Resiliency Demo Topo Dual WAN.png)

## Tests Performed

The failover tests performed measure recovery time for:

- Three events performed ***sequentially***, cumulatively building on each prior event:
  - [WAN Circuit Failure](/v1/docs/graphiant-backbone-resiliency-results#wan-circuit-failure) (Event 1)
  - [PoP Failure](/v1/docs/graphiant-backbone-resiliency-results#pop-failure-test) (Event 2)
  - [Region Failure](/v1/docs/graphiant-backbone-resiliency-results#region-failure-test) (Event 3)
- A ***simultaneous*** test of all three above events occurring at once:
  - [Immediate Region Failure](/v1/docs/graphiant-backbone-resiliency-results#immediate-region-failure-test-event-4) (Event 4)

## WAN Circuit Failure Test (Event 1)

In a WAN Circuit failure test, a WAN connection from the Edge to the Core is brought down.

### WAN Circuit Failure in Single WAN

#### Topology

In the case of a single WAN topology experiencing a primary WAN disconnection, the traffic will move:

***From:*** The primary path to/from the Graphiant PoP

***To:*** The backup path to/from the other PoP in that same region.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating WAN circuit failure in a single WAN topology for client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Single WAN Client(1).png)

![Diagram illustrating WAN circuit failure in a single WAN topology with regions and connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Single WAN Server(3).png)

#### Performance Results: WAN Circuit Failure (Event 1) in Single WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 3 | 3 |
| 2024 | Server Side | 4 | 2 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 3 | 3 |
| 2025 | Server Side | 2 | 3 |

### WAN Circuit Failure in Dual WAN

#### Topology

In the case of a dual WAN topology experiencing a primary WAN disconnection, the traffic will move:

***From:*** The primary path to/from the Graphiant PoP

***To:*** The backup path to/from the other PoP within the same Graphiant region.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating dual WAN topology with a highlighted circuit failure scenario.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Dual WAN Client1.png)

![Diagram illustrating dual WAN topology and circuit failure for server connectivity.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test WAN Circuit Failure Dual WAN Server(3).png)

#### Performance Results: WAN Circuit Failure (Event 1) in Dual WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 3 | 3 |
| 2024 | Server Side | 3 | 2.8 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 2 | 2 |
| 2025 | Server Side | 3 | 3 |

## PoP Failure Test (Event 2)

In a PoP failure test, all connections from the Edge to a given PoP are brought down.

### PoP Failure in Single WAN

#### Topology

> [!NOTE]
> In the case of a single WAN topology PoP disconnection:
> 
> This is the same topology as the WAN circuit failure test, as the prior disconnection of the single WAN circuit results in that PoP no longer being reachable.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating PoP failure in a single WAN topology on the client side.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Single WAN Client(1).png)

![Diagram illustrating PoP failure in a single WAN topology with source and destination.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Single WAN Server(2).png)

#### Performance Results: PoP Failure (Event 2) in Single WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 0 | 0 |
| 2024 | Server Side | 0 | 0 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 0 | 0 |
| 2025 | Server Side | 0 | 0 |

### PoP Failure in Dual WAN

#### Topology

In the case of a dual WAN topology, the original backup path to the PoP will be brought down, secondarily to the primary WAN circuit disconnect.

The traffic will move:

***From:*** The primary path (originally the backup path prior to Event 1) to/from the primary PoP

***To:*** The backup path to/from the other PoP within that same region.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating dual WAN topology with PoP failure and client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Dual WAN Client(1).png)

![Diagram illustrating dual WAN topology and PoP failure between regions A and B.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test PoP Failure Dual WAN Server(3).png)

#### Performance Results: PoP Failure (Event 2) in Dual WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 0 | 0 |
| 2024 | Server Side | 0 | 0 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 0 | 0 |
| 2025 | Server Side | 0 | 0 |

## Region Failure Test (Event 3)

In a Region failure test, all connections from the Edge to the secondary PoP in a given region in the Graphiant Core are brought down.

### Region Failure in Single WAN

#### Topology

In the case of a single WAN topology, the path to the secondary PoP in the region will be brought down, secondarily to the primary PoP disconnect.

The traffic will move:

***From:*** The primary path (originally the backup path prior to Event 1) to/from the secondary PoP

***To:*** The path to/from the next closest PoP in a different region within the Graphiant Core.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating region failure in a single WAN topology for client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Client.png)

![Diagram illustrating single WAN topology with region failure and server connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Server(1).png)

#### Performance Results: Region Failure (Event 3) in Single WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 81 | 110 |
| 2024 | Server Side | 81 | 110 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 76 | 108 |
| 2025 | Server Side | 78 | 111 |

### Region Failure in Dual WAN

#### Topology

In the case of a dual WAN topology, the paths to the secondary PoP in the region will be brought down, secondarily to the primary PoP disconnect.

The traffic will move:

***From:*** The primary path (originally the backup path prior to Event 2) to/from the secondary PoP

***To:*** The path to/from the next closest PoP in a different region within the Graphiant Core.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating dual WAN topology with region failure and client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Client(1).png)

![Diagram illustrating dual WAN topology with region failure and connection paths.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Server(2).png)

#### Performance Results: Region Failure (Event 3) in Dual WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 58 | 112 |
| 2024 | Server Side | 68 | 111 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 59 | 111 |
| 2025 | Server Side | 52 | 56 |

## Immediate Region Failure Test (Event 4)

In an Immediate Region failure test, all connections from the Edge to a given region in the Graphiant Core are brought down simultaneously.

### Immediate Region Failure in Single WAN

#### Topology

In the case of a single WAN topology, after the region is immediately unreachable:

The traffic will move:

***From:*** The path to the primary PoP within a given region

***To:*** The next closest PoP in a different region within the Graphiant Core.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating region failure in a single WAN topology for client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Client.png)

![Diagram illustrating single WAN topology with region failure and server connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Single WAN Server(1).png)

#### Performance Results: Immediate Region Failure (Event 4) in Single WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 71 | 112 |
| 2024 | Server Side | 83 | 114 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 68 | 108 |
| 2025 | Server Side | 84 | 107 |

### Immediate Region Failure in Dual WAN

#### Topology

In the case of a dual WAN topology, after the region is immediately unreachable:

The traffic will move:

***From:*** The primary path to the primary PoP within a given region

***To:*** The next closest PoP in a different region within the Graphiant Core.

**Red** arrows = Blocked path

**Green** arrows = New Primary path

**Yellow** arrows = Backup path

![Diagram illustrating dual WAN topology with region failure and client-side connections.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Client(1).png)

![Diagram illustrating dual WAN topology with region failure and connection paths.](https://cdn.document360.io/d86ecd1c-49f6-4fac-83cc-5e344f28f84f/Images/Documentation/Backbone Failover Test Region Failure Dual WAN Server(2).png)

#### Performance Results: Immediate Region Failure (Event 4) in Dual WAN Topology

| Year | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- |
| 2024 | Client Side | 73 | 115 |
| 2024 | Server Side | 66 | 113 |
| **Year** | Topology | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | Client Side | 70 | 112 |
| 2025 | Server Side | 83 | 108 |

## Complete Performance Results per Topology

### Single WAN, Failure on Client Side

| Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- | --- |
| 2024 | 1 | WAN Circuit Failure | 3 | 3 |
| 2024 | 2 | add PoP Failure | 0 | 0 |
| 2024 | 3 | add Region Failure | 81 | 110 |
| 2024 | 4 | Immediate Region Failure | 71 | 112 |
| **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | 1 | WAN Circuit Failure | 3 | 3 |
| 2025 | 2 | add PoP Failure | 0 | 0 |
| 2025 | 3 | add Region Failure | 76 | 108 |
| 2025 | 4 | Immediate Region Failure | 68 | 108 |

### Single WAN, Failure on Server Side

| Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- | --- |
| 2024 | 1 | WAN Circuit Failure | 4 | 2 |
| 2024 | 2 | add PoP Failure | 0 | 0 |
| 2024 | 3 | add Region Failure | 81 | 110 |
| 2024 | 4 | Immediate Region Failure | 83 | 114 |
| **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | 1 | WAN Circuit Failure | 2 | 3 |
| 2025 | 2 | add PoP Failure | 0 | 0 |
| 2025 | 3 | add Region Failure | 78 | 111 |
| 2025 | 4 | Immediate Region Failure | 84 | 107 |

### Dual WAN, Failure on Client Side

| Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- | --- |
| 2024 | 1 | WAN Circuit Failure | 3 | 3 |
| 2024 | 2 | add PoP Failure | 0 | 0 |
| 2024 | 3 | add Region Failure | 58 | 112 |
| 2024 | 4 | Immediate Region Failure | 73 | 115 |
| **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | 1 | WAN Circuit Failure | 2 | 2 |
| 2025 | 2 | add PoP Failure | 0 | 0 |
| 2025 | 3 | add Region Failure | 59 | 111 |
| 2025 | 4 | Immediate Region Failure | 70 | 112 |

### Dual WAN, Failure on Server Side

| Year | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| --- | --- | --- | --- | --- |
| 2024 | 1 | WAN Circuit Failure | 3 | 2.8 |
| 2024 | 2 | add PoP Failure | 0 | 0 |
| 2024 | 3 | add Region Failure | 68 | 111 |
| 2024 | 4 | Immediate Region Failure | 66 | 113 |
| **Year** | Event # | Event Type | Ping Recovery Time (seconds) | Iperf3 TCP Recovery Time (seconds) |
| 2025 | 1 | WAN Circuit Failure | 3 | 3 |
| 2025 | 2 | add PoP Failure | 0 | 0 |
| 2025 | 3 | add Region Failure | 52 | 56 |
| 2025 | 4 | Immediate Region Failure | 83 | 108 |
